Current Location:Home>HAIPO News>News CenterCauses of Thermal Imbalance in Insulated-Pipe District Heating

Causes of Thermal Imbalance in Insulated-Pipe District Heating

Source:http://www.sdhpgy.com Date:2019-07-03 Posted by:admin
Thermodynamic imbalance in heat-insulating pipe central heating system should be analyzed in detail. Under normal conditions, the problem of temperature imbalance can be well handled by choosing optimal heat source equipment, ensuring adequate heat supply, or changing user heat exchangers to improve the heat exchange efficiency of heat exchangers after checking and confirming the reasons.
Hydraulic imbalance of heat preservation pipe central heating system is becoming more and more common and diverse, including:
Application of throttle valve. The use of conditioning valve is an important measure to alleviate the thermal imbalance of central heating system and ensure the hydraulic balance. There are three main types of regulating valves used in heat preservation pipeline network: static regulating valves, dynamic flow equalizing valves and dynamic differential pressure equalizing valves.
In detail, the static conditioning valve plays a fundamental role in hydraulic balancing. Its working principle is to adjust the resistance in the pipeline to reach the purpose of orifice plate conditioning, and then balance the resistance in the insulation pipe network. Therefore, the static conditioning valve is an artificial conditioning operation.

Jinan Insulated Pipe
Dynamic flow equalization valve, also known as self-operated flow control valve, is an important equipment to complete the hydraulic equalization of the pipeline network. Detailed working principle is that according to the different pressures of the front and back of the valve, the valve stops automatically opening large or small to ensure that the flow is constant and the flow is controlled reasonably. Constant flow conditioning valve is a new type of dynamic flow control equipment, which can complete the flow self-regulation of each loop and ensure the hydraulic balance of the thermal pipe network. Compared with the original conditioning valves, all series of constant flow conditioning valves can be equipped with electric actuators, and connected to the automatic control system of the heating network to complete the automatic control of the heating system. Compared with the original manual control valve, the constant flow control valve is more convenient, simple and intelligent, and the cost of the device is not high.
State pressure differential equalization valve, also known as self-balancing valve, is a kind of system which provides data reference for the regulation of thermal pipe network after measuring and debugging the pressure difference. The detailed working principle is that when the flow in the insulation pipe changes, the valve core of the self-balancing valve will move up and down accordingly. Thus, the flow area of the self-balancing valve will be moved up and down. Flow coefficient and flow coefficient will become different, but in different locations will always ensure that the spool and seat are balanced, to ensure that the differential pressure value remains unchanged. Usually, the dynamic differential pressure equalization valve should stop the device at each control node to complete the overall monitoring of the thermal network.
(2) Application of pressure pump. The use of pressurized pumps mainly refers to the use of pressurized pumps at the disadvantageous end of heating, which is another important measure to deal with the hydraulic imbalance of the thermal pipe network and ensure the hydraulic balance. This is because the practice head and flow of circulating water pump in heating system are not fixed and have been adhering to sufficient conditions, so in practice, there will be insufficient practice head and flow of circulating water pump in heat insulation pipe network, which will inevitably lead to the lack of capital pressure head or flow at the disadvantageous end of distant heating. Therefore, installing water pumps in heat exchanger stations of unfavorable end users will help to ensure the heating flow of unfavorable end users.
Attention should be paid to installing water pumps in heat exchanger stations, which should be carefully selected and reasonably installed to prevent the flow rate affecting other users around them from forming more serious hydraulic imbalances, such as "water grabbing" problems. To select pumps, one needs to understand the known parameters in the heat exchanger station, and the other needs to understand the detailed information of pressure head and flow. Separation of the two is used as a reference criterion for selecting pumps. Usually, small pressurized pumps are enough to meet the needs of most users. At present, the types of pumps are rich and varied, and the technology is mature. There are small flow, small lift, low noise, maintenance-free pumps, and three-speed variable-speed pumps with higher technical content, and continuously variable-speed pumps with frequency conversion (flow, temperature, pressure, differential pressure).
(3) The optimization of heating system equipment. The optimization of heating system equipment is mainly concerned with aging, unqualified and unreasonable pipes, boilers with low heating efficiency and heat exchangers with low heat energy conversion rate, etc. to stop the optimization and transformation, to improve the heat of heat preservation pipe central heating system, to reduce the loss and loss in heat storage, to improve the conversion rate of secondary heat energy and to reduce it. Presentation of thermodynamic imbalance. To sum up, there are mainly two kinds of thermal imbalance in heat-supply system of insulation pipe: temperature imbalance and hydraulic imbalance. In view of the difference between the two practical conditions, different targeted treatment methods are selected and adopted, which can greatly deal with the thermal imbalance problem and ensure the smooth operation and balanced distribution of central heating system. Promote the promotion of central heating system.

Best-Selling Products:   PU Insulated Steel Pipe Manufacturer Jinan Insulated Pipes Black-Jacketed Direct-Buried LSAW Pipe

Shandong HAIPO Piping Technology Development Co., Ltd.  
Tel:13953119851 Landline:0531—67819251 Address:No. 9017 Jinlun Road, South Park, Jinan Economic Development Zone, Changqing District, Jinan, Shandong, China

Website:https://www.sdhpgy.com/english  

[Images on this site are provided by the site owner. Some are sourced from the internet. If any copyright is infringed, please contact us and we will remove the material immediately.]